Investigating optimum cooling set point temperature and air velocity for thermal comfort and energy conservation in mixed-mode buildings in India

  • In warm and hot climates, ceiling fans and/or air conditioners (ACs) are used to maintain thermal comfort. Ceiling fans provide air movement near the skin, which enhances the evaporation of sweat, reduces heat stress, and enhances thermal comfort. This is also called the cooling effect. However, AC usage behaviour and the effects of elevated air speed through the use of ceiling fans on indoor operative temperature during AC usage are not widely studied. This study investigated the optimum AC (cooling) set point temperature and air velocity necessary for maintaining thermal comfort while achieving energy conservation, in mixed-mode buildings in India, through field studies by using used custom-built Internet of Things (IOT) devices. In theIn warm and hot climates, ceiling fans and/or air conditioners (ACs) are used to maintain thermal comfort. Ceiling fans provide air movement near the skin, which enhances the evaporation of sweat, reduces heat stress, and enhances thermal comfort. This is also called the cooling effect. However, AC usage behaviour and the effects of elevated air speed through the use of ceiling fans on indoor operative temperature during AC usage are not widely studied. This study investigated the optimum AC (cooling) set point temperature and air velocity necessary for maintaining thermal comfort while achieving energy conservation, in mixed-mode buildings in India, through field studies by using used custom-built Internet of Things (IOT) devices. In the current study, the results indicate a 79% probability that comfort conditions can be maintained by achieving a temperature drop of 3K. If this drop can be achieved, as much as possible, through passive measures, the duration of AC operation and its energy consumption are reduced, at least by 67.5 and 58.4%, respectively. During the air-conditioned period, there is a possibility that the cooing effect is reduced because of increase in operative temperature due to ceiling fan operation. Therefore, the optimum solution is to maintain the highest AC set point and minimum fan speed setting that are acceptable.show moreshow less

Download full text files

Export metadata

Additional Services

Search Google Scholar    

Statistics

frontdoor_oas
Metadaten
Document Type:Peer-Reviewed Article
Author:Sriraj Gokarakonda, Christoph van Treeck, Rajan Rawal
URN (citable link):https://nbn-resolving.org/urn:nbn:de:bsz:wup4-opus-79375
DOI (citable link):https://doi.org/10.3390/en15062259
Year of Publication:2022
Language:English
Source Title (English):Energies
Volume:15
Issue:6
Article Number:2259
Divisions:Energie-, Verkehrs- und Klimapolitik
Dewey Decimal Classification:600 Technik, Medizin, angewandte Wissenschaften
OpenAIRE:OpenAIRE
Licence:License LogoCreative Commons - CC BY - Namensnennung 4.0 International