To achieve the EU's energy efficiency targets, both the rate of building energy renovation and its depth, i.e., the amount of energy savings post renovation need to be improved. Energy Performance Certificates (EPCs) are key to make energy efficiency measures transparent for the building market and to promote the energy efficiency of buildings through renovation. The revision of the Energy Performance of Buildings Directive (EPBD) is seen as a pre-condition to meet the Renovation Wave objectives and to reach a highly energy efficient and decarbonized building stock by 2050. One focus of the current revision of the EPBD is therefore the improvement of EPCs. QualDeEPC - High-quality Energy Performance Assessment and Certification in Europe Accelerating Deep Energy Renovation, funded under the EU's Horizon 2020 programme, is a project that aims to improve EPCs. Following an EU-wide review of existing EPC schemes, and extensive stakeholder discussions in the seven partner countries, QualDeEPC found that EPCs and EPC schemes need to enhance particularly in the following three ways:
1. Establish a close link between EPCs and deep energy renovation
2. Improve the quality of EPC schemes, i.e., both the EPCs and their data, and the processes of assessment, certification, verification
3. Improve cross-EU convergence of EPC schemes.
In warm and hot climates, ceiling fans and/or air conditioners (ACs) are used to maintain thermal comfort. Ceiling fans provide air movement near the skin, which enhances the evaporation of sweat, reduces heat stress, and enhances thermal comfort. This is also called the cooling effect. However, AC usage behaviour and the effects of elevated air speed through the use of ceiling fans on indoor operative temperature during AC usage are not widely studied. This study investigated the optimum AC (cooling) set point temperature and air velocity necessary for maintaining thermal comfort while achieving energy conservation, in mixed-mode buildings in India, through field studies by using used custom-built Internet of Things (IOT) devices. In the current study, the results indicate a 79% probability that comfort conditions can be maintained by achieving a temperature drop of 3K. If this drop can be achieved, as much as possible, through passive measures, the duration of AC operation and its energy consumption are reduced, at least by 67.5 and 58.4%, respectively. During the air-conditioned period, there is a possibility that the cooing effect is reduced because of increase in operative temperature due to ceiling fan operation. Therefore, the optimum solution is to maintain the highest AC set point and minimum fan speed setting that are acceptable.