Volltext-Downloads (blau) und Frontdoor-Views (grau)
  • search hit 1 of 3
Back to Result List

Energy performance of room air-conditioners and ceiling fans in mixed-mode buildings

  • Studies show that people can tolerate elevated temperatures in the presence of appreciable air movement (e.g., from using ceiling fans). This minimises the use of air-conditioners and extends their set-point temperature (Tset), resulting in energy savings in space cooling. However, there is little empirical evidence on the energy savings from using ceiling fans with Room Air-Conditioners (RACs). To address this gap, we analysed the energy performance of RACs with both fixed-speed compressors and inverter technology at different set-point temperatures and ceiling fan speed settings in 15 residential Mixed-Mode Buildings (MMBs) in India. Thermal comfort conditions (as predicted by the Indian Model for Adaptive Comfort-Residential (IMAC-R))Studies show that people can tolerate elevated temperatures in the presence of appreciable air movement (e.g., from using ceiling fans). This minimises the use of air-conditioners and extends their set-point temperature (Tset), resulting in energy savings in space cooling. However, there is little empirical evidence on the energy savings from using ceiling fans with Room Air-Conditioners (RACs). To address this gap, we analysed the energy performance of RACs with both fixed-speed compressors and inverter technology at different set-point temperatures and ceiling fan speed settings in 15 residential Mixed-Mode Buildings (MMBs) in India. Thermal comfort conditions (as predicted by the Indian Model for Adaptive Comfort-Residential (IMAC-R)) with minimum energy consumption were maintained at a set-point temperature (š¯‘‡set) of 28 and 30 C and a fan speed setting of one. Compared with a Tset of 24 Ā°C, a š¯‘‡set of 28 and 30 Ā°C resulted in energy savings of 44 and 67%, respectively. With the use of RACs, a configuration with a minimum fan speed was satisfactory for an optimal use of energy and for maintaining the conditions of thermal comfort. In addition, RACs with inverter technology used 34-68% less energy than fixed-speed compressors. With the rising use of RACs, particularly in tropical regions, the study's outcomes offer a significant potential for reducing space-cooling energy consumption and the resultant greenhouse gas (GHG) emissions.ā€¦show moreshow less

Download full text files

Export metadata

Additional Services

Search Google ScholarĀ Ā Ā Ā 

Statistics

frontdoor_oas
Metadaten
Document Type:Peer-Reviewed Article
Author:Sriraj Gokarakonda, Christoph van Treeck, Rajan Rawal, Stefan ThomasORCiDGND
URN (citable link):https://nbn-resolving.org/urn:nbn:de:bsz:wup4-opus-84025
DOI (citable link):https://doi.org/10.3390/en16196807
Year of Publication:2023
Language:English
Source Title (English):Energies
Volume:16
Issue:19
Article Number:6807
Divisions:Energie-, Verkehrs- und Klimapolitik
Dewey Decimal Classification:690 Hausbau, Bauhandwerk
OpenAIRE:OpenAIRE
Licence:License LogoCreative Commons - CC BY - Namensnennung 4.0 International