Refine
Has Fulltext
- yes (2)
Year of Publication
- 2019 (2) (remove)
Document Type
Language
- English (2)
Division
India's present development trajectory is at a crucial juncture with a requirement to meet the demands of a population of over 1.2 billion while ensuring environmental sustainability. The resulting economic growth over the past two decades has over-exploited finite natural resources and led to tremendous environmental degradation. Therefore, decoupling economic growth from resource consumption is crucial in the transformation towards a green economy. Building construction is one of the most resource-intensive sectors, as well as creating a high impact on the environment. This study analyzes existing mechanisms in India's building construction sector that attempt to decouple economic growth from resource use and environmental impacts. The key contributors for decoupling are analyzed. Recommendations for regulations, market incentives, transparency, data monitoring and capacity-building are provided for an array of policy initiatives targeted at political and financial decision-makers at the national, state and local levels for different buildings.
The potential of mixed-mode office buildings with varying design and control parameters is examined by using an uncertainty analysis in the three climate zones of India. The analysis is in terms of cooling energy consumption, thermal comfort conditions, and natural ventilation hours. Furthermore, influential parameters are identified using sensitivity analysis. In this study, opening the windows enables natural ventilation. Night-time ventilation through the windows is not enabled because these are mostly closed at night. A maximum natural ventilation of 10% of the total building occupancy hours are observed in warm and humid, and hot and dry climates; however, they are slightly higher in the composite climate. A further increase in the number of natural ventilation hours leads to an increase in the occupancy hours outside the Indian Model for Adaptive Comfort model for mixed-mode buildings with at least 90% of occupants are satisfied. There are no occupancy hours outside of 80% of occupants are satisfied. The choice of thermal comfort band is crucial for determining the potential of mixed-mode buildings. The cooling setpoint temperature, building size, window solar heat gain coefficient, and surface properties of exterior surfaces are identified as the more influential parameters than the thermophysical properties of building envelope constructions. Although the building envelope which is in compliance with the Energy Efficient Building Code of India increases energy efficiency during air-conditioning periods, whether it reduces natural ventilation hours, because of overheating during such period remains to be determined.